Sign In | Join Free | My ecer.co.uk
China DAMAI TECH  CO.,LIMITED. logo
DAMAI TECH CO.,LIMITED.
DaMai Medical Co.,Ltd.
Verified Supplier

2 Years

Home > ENT Probe >

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma

DAMAI TECH CO.,LIMITED.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma

  • 1
  • 2

Technology : Low Temperature Radiofreqency Plasma

Payment Terms : L/C,T/T

Product Name : Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand

Model Number : VF10E

Cutting Principle : Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.

MOQ : 1 Set

Delivery Time : 5-8 days

Working Mode : Ablation and resection: level 1-10, Coagulation: level 1-10

Price : 3200-8600USD

Type : Needle, Hook, Other, Knife, Sinus Forceps

Certification : ISO, CE

Input Volt : 198-242V 50Hz

Place of Origin : China

Supply Ability : 100000 sets per year

Feature : Reusable, Minimally Invasive, less Pain, Low Working Temperature, no Bleeding

Brand Name : Better

Packaging Details : Standard Carton

Contact Now

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma Technology for High Standards
Product Overview
The VF10E ENT Plasma Surgery System is a professional minimally invasive surgical device specially developed for otological and ear canal lesion treatment. Designed for precise ear surgery intervention, the system delivers accurate plasma cutting and effective hemostasis targeting subtle lesions in delicate ear structures.

This surgical plasma device is applicable for the cutting and hemostasis of lesions occurring on external auditory canal walls, bone sutures, promontory, and tympanic chambers. In addition to conventional ear lesion resection and hemostatic management, it also serves as an effective surgical adjuvant treatment solution for cochlear and internal auditory canal lesions.

Adopting advanced low-temperature plasma technology, the VF10E system ensures stable and controlled energy output during surgery. It minimizes thermal trauma to surrounding normal ear tissues, reduces intraoperative bleeding, and improves the clarity of the surgical field. Featuring precise lesion targeting and flexible adaptability for fine otological operations, it provides safe, efficient and reliable minimally invasive treatment for specialized ENT clinical procedures.
Key Features
  • Product Names: Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma Technology for High Standards
  • Features: Reusable, Minimally Invasive, Less Pain, Low Working Temperature, No Bleeding
  • Output Power: Ablation and resection ≤360W, Coagulation and hemostasis ≤110W
Technical Specifications
Material Stainless Steel, Copper, Medical Grade German Stainless Steel
Application Cutting and hemostasis of lesions in external auditory canal walls, bone sutures, promontory, and tympanic chambers;
Surgical adjuvant treatment for cochlear and internal auditory canal
lesions
Input Voltage 198-242V 50Hz
Function Cutting and hemostasis of lesions in external auditory canal walls
Dimensions 409*460*145mm (L*W*H)
Properties ENT Surgical Instruments
Product Advantage Minimally Invasive, low temperature, short hospital time
Brand Coblator II
Weight 7kg
Medical Applications
  • Cutting and hemostasis of lesions in external auditory canal walls
  • Bone sutures, promontory, and tympanic chambers
  • Surgical adjuvant treatment for cochlear and internal auditory canal lesions
Certification & Ordering
Certified by ISO and CE. Manufactured in China.
  • Minimum Order Quantity: 1 set
  • Price Range: $3,200-$8,600 USD
  • Payment Terms: L/C, T/T, MoneyGram
  • Supply Ability: 100,000 sets annually
  • Packaging: Standard carton
Support & Services
Our technical support team is available 24/7 to answer questions and provide troubleshooting assistance. We offer comprehensive training and education services to ensure user proficiency, along with maintenance and repair services to keep devices in optimal condition.
Packaging & Shipping
Product Packaging: Plasma Surgery ENT Probe, User Manual, Protective Cap, Storage Case
Shipping: Ships within 7-12 business days. Free standard shipping within the United States. International shipping available at additional cost. Tracking information provided.
Frequently Asked Questions
Brand: Better
Model Number: VF10E
Certifications: ISO and CE
Minimum Order Quantity: 1 set
Price Range: $3,200-$8,600 USD
Payment Terms: L/C, T/T
Supply Ability: 100,000 sets per year
Packaging: Standard carton

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma


Product Tags:

ENT probe with radiofrequency plasma technology

      

low temperature surgical ENT instruments

      

precise external auditory canal wand

      
Quality Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma for sale

Low Temperature Precise Surgical Ent Instruments Cutting and hemostasis of lesions in external auditory canal walls Wand Radiofrequency Plasma Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DAMAI TECH CO.,LIMITED.
*Subject:
*Message:
Characters Remaining: (0/3000)